    Glossary of Switch Terms

    Actuator: The mechanical interface between the basic switch contacts and the means of operation, such as the operator’s finger.

    Actuation Force: The required force to change a circuit’s electrical state.

    Alternate Action Switch: A Pushbutton style switch where the change of the electrical state is maintained between actuations.

    Ampere: A unit of electrical current flow.

    Base (Housing): A base of a switch is the main member to which the conducting parts or insulator unit are attached. It may also have parts of the operating or control mechanism attached.

    Bounce: Rebounding of moving contact against fixed contact during transfer.

    Break: Interruption of a circuit. Double-break occurs when a single mechanism interrupts two contacts simultaneously.

    Break Before Make: The term given to a double throw switch where the first circuit is opened before the second circuit is closed.

    Capacity: Usually refers to the current handling capability of a switch.

    Chatter: Rapid opening and closing of contacts, usually exhibited during extreme vibration and/or shock.

    Clearance (Spacing): Distance through air between electrically live parts of opposite polarity or to ground.

    Contact: The contact is a conducting part designed to be united by pressure to another conducting part for the purpose of carrying current.

    Contact Bounce: Oscillation of the movable contact upon closure of the circuit.

    Contact Gap: The minimum distance between the fixed and moveable contacts.

    Contact Resistance: The resistance of current flow across closed contacts.

    Dead-Break: Open circuit condition, usually caused when slowly actuating snap-action switches. Results from low contact pressure or contact lift-off.

    Detent: Feature that indicates actuation point has been reached. Can also be referred to as tactile feel.

    Dielectric Strength: The ability of an insulating material to resist voltage from arcing across its surface.

    Differential: Distance between trip point (or force) and reset point (or force).

    Double-Break: A mechanism that breaks the circuit at two points simultaneously by means of a “shorting bar” like device.

    Double-Throw: Contact arrangement that alternately transfers normally open and normally closed circuits.

    Dust-Tight: Sealed switch will withstand sand and dust contamination.

    Electrical Life: Expected cycle life when switch is operated at full rated load.

    Free Position: Point at which plunger exists in the un-operated condition.

    Insulation Resistance: The resistance to current flow of the insulating materials between contacts.

    Lever Actuator: A device, hinged or spring type, applied to a basic switch to facilitate its application.

    Make Before Break: The term given to a double throw switch when the second circuit is closed before the first circuit is opened.

    Momentary Action Switch: The term given to a switch where a circuit is continuously closed or opened only when force is applied. The electrical state returns to its normal position when the force is removed.

    Normally Closed: The term given to a switch where a circuit is closed in the normal switch position.

    Normally Open: The term given to a switch where a circuit is open in the normal switch position.

    Operating Point: Point at which contacts transfer. Usually measured from the switch mounting holes.

    Over Travel: The distance an actuator travels after the circuit is closed.

    Pole: The term to denote a completely separate circuit, which passes through a switch at one time.

    Pre Travel: The movement of the actuator prior to closing the circuit. Sometimes identical to “Travel to Make”.

    Reset Point: Point at which contact resumes normal position. Single-Break: Mechanism that transfers one contact.

    Single Throw Switch: A single throw switch is a switch by means of which the circuit can be opened or closed by moving the switch blade into or out of one set of contacts only.

    Snap Action: The abrupt transfer of contacts from one position to another. This action is relatively
    independent of the speed of actuator travel.

    Splash Proof: Sealed switch will withstand heavy rain or stream of water.

    Switch: A switch is a device for making, breaking, or changing the connections in an electric circuit.


    Switch Abbreviations:

    N.C.: Normally Closed circuit

    N.O.: Normally Open circuit

    SPST: Single Pole Single Throw

    SPDT: Single Pole Double Throw

    DPST: Double Pole Single Throw

    DPDT: Double Pole Double Throw

    MBB: Make Before Break

    BBM: Break Before Make

    Throw: The term denotes the number of positions in which a given pole is closed.

    Travel to Make: The distance parallel to the designated direction of the actuator movement at which point a circuit is closed.

    Watertight: Sealed switch will withstand submersion to various depths depending on specification level.

    Wiping Action: Lateral travel of movable contact over fixed contact while pressure between the two contacts exists. Occurs during plunger travel. This action helps clean the contacts of contamination.

    |